Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woodmart domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home4/viaaqua0/public_html/wp-includes/functions.php on line 6114

Warning: Cannot modify header information - headers already sent by (output started at /home4/viaaqua0/public_html/wp-includes/functions.php:6114) in /home4/viaaqua0/public_html/wp-includes/feed-rss2.php on line 8
PUMPS/POWERHEADS – Technological Aquatic Associated Manufacturing https://viaaqua.net Thu, 23 Mar 2023 08:50:09 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 https://viaaqua.net/wp-content/uploads/2020/10/cropped-logo-icon-32x32.png PUMPS/POWERHEADS – Technological Aquatic Associated Manufacturing https://viaaqua.net 32 32 12 volt Low Voltage UL Pumps https://viaaqua.net/product/12-volt-low-voltage-ul-pumps Thu, 23 Mar 2023 08:50:09 +0000 https://viaaqua.net/?post_type=product&p=7427
  • Efficient design
  • Fully submersible
  • Multi-purpose
  • Quiet running
  • Oil-free motor
  • Low voltage transformer included
  • ]]>
  • Models:

    model Item no. Dimension
    (L x W x H)
    Flow rate max. head wattage UPC# 0069037
    VA 40UL 1.5″ x 1.5″ x 1 “ 40 GPH 2 ft. 2 w 1308 5
    VA 50UL 1.5″ x 1.5″ x 1 “ 50 GPH 2.15 ft. 2 w 1470 9
  • Installation:

    Inside aquariums, fountains and waterfalls
    Application: Wet and Dry filtering systems, sumps and protein skimmers (in-sump).
    Follow all safeguards and safety guidelines:

    • ViaAqua® pump must be operated fully submersed at all times.
    • Do not reduce the input of the pump.
    • Verify that the pump size fits the application without dramatically restricting the flow. Consult your local dealer or manufacturer’s guidelines for the proper size and model of ViaAqua® pump.
    • When connecting flexible tubing to the intake of the pump use a hose clamp to insure water tightness.
    • Use a float valve to insure a consistent water level and to insure the pump is operated fully submersed at all times.
    • When connecting flexible tubing to the intake of the pump use a hose.

    Under-gravel Filtration System

    • Remove the main housing strainer and attach the undergravel filter strainer to the intake of the pump. Next attach the undergravel filter adapter to the undergravel filter strainer.
    • Position the pump where as it will be fully submersed at all times. This may take some modifications to the uplift tube of the undergravel filter.
    • Use the provided suction cups or pump hanger to secure the pump on the back wall of the aquarium.
    • Replace the impeller if there are any signs of excess wear or damage.
    • Failure to maintain a ViaAqua® pump will cause permanent damage to the impeller and/or the pump. Routine maintenance is of the utmost importance to keep your pump working well.
    • Verify that there is not any gravel in the uplift tube and/or U.G. filter strainer. Failure to do so will cause damage to the pump.

    Note: If air and water is desired to be discharge from the pump, follow next step.

    • Remove the air stopper from the venturi discharge and connect a piece tubing and air silencer to the venturi discharge.
    • If the pump is more than 4” below the surface of the water, the venturi will not work. The Airline tubing and silencer must be out of water to suck in air.
    Download
     Low Voltage UL pump Instructions.

    If you have problem opening PDF file from Internet Explorer,
    please try Firefox or right click on the link and select Save Target As and save the PDF file in your computer.

  • Maintenance:To ensure a properly operating pump: Clean pump, impeller and intake strainer every 3 weeks. Failure to do so will cause premature failure of the pump.

    • Disconnect the pump from the power supply prior to removing the pump from the water.
    • Remove either the prefilter or intake filter strainer. Rinse out prefilter sponge of debris.
    • Remove the impeller well cover.
    • Once the impeller well cover is removed, slide both the impeller and shaft out of the main body of the pump and clean well. Do not use any soap detergents during cleaning.
    • After the impeller and shaft are cleaned, use a small brush to clean inside of the motor housing.
    • Reassemble above parts and your ViaAqua® pump is again ready to use. Confirm that all the washer and bushing a reassembled properly. Failure to do so will cause permanent damage to the pump.
    • Replace the impeller if there are any signs of damage or excess wear.
  • ]]>
    Internal Filter Pumps https://viaaqua.net/product/internal-filter-pumps Thu, 23 Mar 2023 08:47:15 +0000 https://viaaqua.net/?post_type=product&p=7423
  • Compact design and energy efficient
  • User friendly
  • Simple installation
  • Ideal for small water fountain and waterfall
  • Great for desktops fountain
  • ]]>
  • Models:

    model Item no. Dimension
    (L x W x H)
    Flow rate max. head wattage UPC# 0069037
    VA 80PF 1.75″ x 1.25″ x 5.25 “ 80 GPH 23 in. 4 w 1617 8
    VA 302PF 2″ x 1.75″ x 5.25 “ 130 GPH 27 in. 6 w 1385 6
    VA 305PF 3″ x 2.25″ x 7.5 “ 315 GPH 51 in. 18 w 1486 0
    VA 306PF 3.5″ x 3″ x 9″ 525 GPH 71 in. 35 w 1487 7
  • ]]>
    Economy Pumps https://viaaqua.net/product/economy-pumps Thu, 23 Mar 2023 08:44:52 +0000 https://viaaqua.net/?post_type=product&p=7420
  • Models:

    Item no. Dimension
    (L x W x H)
    Flow rate max. head wattage UPC# 0069037
    VA80 1.75″ x 1.25″ x 1.75 “ 80 GPH 23 in. 4 w 1485 3
    VA 302 2″ x 1.75″ x 2 “ 130 GPH 27 in. 6 w 1382 5
    VA 305 3″ x 2.25″ x 3.5 “ 315 GPH 51 in. 18 w 1383 2
    VA 306 3.5″ x 3″ x 3.75″ 525 GPH 71 in. 35 w 1384 9
  • Instruction:

    Click Here to download Instruction (PDF)

    If you have problem opening PDF file from Internet Explorer,
    please try Firefox or right click on the link and select Save Target As and save the PDF file in your computer.

  • ]]>
    Economy Pump https://viaaqua.net/product/economy-pump Thu, 23 Mar 2023 08:35:44 +0000 https://viaaqua.net/?post_type=product&p=7414
  • Feature:

  • • Energy Efficient
    • Fully submersible
    • Quiet operation
    • Compact Design
    • For use in fresh & saltwater environments

    ViaAqua® Submersible Water Pumps, the energy efficient and versatile water pump. Enhanced motor design and magnetic rotor technology makes these units energy efficient and silent, yet are powerful and reliable

  • Models:

    Item No. Dimension
    (L x W x H)
    Gallons Per Hour Output Max. Head Wattage UPC No.
    VA-300 1.52″ x 1.51″ x 1.17″ 58 GPH 3/8″ 24″ 2 w 006903735490
    VA-301 1.75″ x 2.10″ x 1.20″ 79 GPH 1/2″ / 3/8″ 26″ 4w 006903714853
    VA 302 1.78″ x 2.10″ x 2.02″ 158 GPH 1/2″ / 3/8″ 35″ 8 w 006903713825
    VA-303 1.78″ x 2.54″ x 2.10″ 211 GPH 1/2″ / 3/8″ 43″ 12 w 006903735506
    VA-304 2.05″ x 2.85″ x 2.52″ 317 GPH 1/2″ / 3/8″ 51″ 15 w 006903735513
    VA 305 2.25″ x 3.36″ x 2.95″ 396 GPH 1/2″ / 5/8″ /
    3.4″
    63″ 25 w 006903713832
    VA 306 2.66″ x 3.64″ x 3.41″ 528 GPH 1/2″ / 5/8″ /
    3.4″
    79″ 35 w 006903713849
  • ]]>
    Hydrant Pumps https://viaaqua.net/product/hydrant-pumps Thu, 23 Mar 2023 08:31:26 +0000 https://viaaqua.net/?post_type=product&p=7410
  • Multi-purpose submersible and external energy efficient for aquarium and pond pump
  • Thermally protected
  • Internal and external operation
  • Pre-filter hose fittings included
  • 16 ft. grounded cord
  • For indoor and outdoor use
  • Extremely quiet
  • ]]>
  • Models:

    Item no. Dimension
    (L x W x H)
    Flow rate max. head wattage UPC# 0069037
    MP 5500 12.5″ x 4.75″ x 5.75 “ 1536 GPH 10.5 in. 117 w 1073 2
    MP 6500 12.5″ x 4.75″ x 5.75 “ 1810 GPH 12.5 in. 124 w 1071 8
    MP 7500 12.5″ x 4.75″ x 5.75 “ 2019 GPH 13.5 in. 127 w 1081 7
    MP 8500 12.5″ x 4.75″ x 5.75 “ 2069 GPH 15.1 in. 165 w 1072 5
    MP 9500 12.5″ x 4.75″ x 5.75 “ 2510 GPH 10.5 in. 192 w 1080 0
  • Parts:

    Model no. PART LIST INSTALLATION
    MP5500, MP6500, MP7500, MP8500, MP9500 Part list for all models Setup for all models
    A. O-rings (6)
    B. 3/4 in. FPT adaptor
    C. 1 in. FPT adaptor
    D. Threaded pump adaptor (2)
    E. 1 1/4 in. barded input/output
    F. 3/4 – 1 in. barbed output
  • Installation:

    In-line or submersed operation
    Follow all safeguards and safety guidelines:

    1. Verify that the pump size fits the application without dramatically restricting the flow. Consult with your local dealer or manufacture’s guidelines fro the size pump needed for your specific application.
    2. Do not reduce the input diameter of the pump
    3. You must incorporate a prefilter when operation for a water circulation, waterfalls, ponds and fountains.
    4. Replace the impeller if there are any signs of damage or excess wear.
    5. Failure to maintain a ViaAqua pump will cause permanent damage to the impeller and/or pump. Routine maintenance is of the utmost importance to keep you pump working well.

    Internal operation: Submersed

    1. Place pump in the desired location
      • If place in a pond: Raise the pump off the bottom of the pond by a min. of 6 inches when installing.
    2. Use Teflon tape to connect the threaded pipe adapter to the output of the pump.
    3. Place the gasket onto the barbed pipe adapter, now using Teflon tape hand tighten the barbed pipe adapter to the threaded pipe the adapter.
    4. Connect the flexible tubing to the barbed pipe adapter. Insure water tightness with a hose clamp

    In-line Operation: External

    1. Place the pump in desired location
    2. Using Teflon tape connect the threaded pipe adapter to the intake and output of the hydrant water pump.
    3. Place a gasket on the barbed pipe adapter, now using Teflon tape hand tighten the barbed pipe adapter to the threaded pipe the adapter.
    4. Connect the flexible tubing to the barbed pipe adapter. Insure water tightness with a hose clamp.
    5. Verify that there are not any kinks in the tubing
    6. The intake must have an adequate strainer. Do to the water flow of the pump a large strainer is required.
    Download
     Hydrant Pump Instructions.

    If you have problem opening PDF file from Internet Explorer,
    please try Firefox or right click on the link and select Save Target As and save the PDF file in your computer.

  • Maintenance:

    • Disconnect the pump from the GFCI power supply prior to removing the pump from the water
    • Remove the prefilter and rinse the prefilter sponge of all debris
    • With a Philips screw driver loosen the four screws on the volute. Now remove the volute.
    • Once the volute is removed clean well. Now verify the impeller is free of all dirt and debris.
    • Remove the impeller and clean well.
    • Reassemble: It may be necessary to add a small amount of silicone lubricant to the gasket in the volute to insure a proper seal.

    Note: If the water flow decreased, it is a clear sign that debris is in the impeller well or the prefilter is clogged. It is the aquarist’s sole responsibility to ensure the pump is maintained. Failure to do so will cause permanent damage to the pump.

  • ]]>
    PowerHead Pumps https://viaaqua.net/product/powerhead-pumps Thu, 23 Mar 2023 08:28:25 +0000 https://viaaqua.net/?post_type=product&p=7406
  • Standard Mode:

    model Item no. Dimension
    (L x W x H)
    Flow rate max.
    head
    wattage UPC# 0069037
    VA 40 1.35″ x 1.25″ x 1″ 40 GPH 23 in. 2 w 1307 8
    VA 100 2.25″ x 1.5″ x 1.8″ 100 GPH 40 in. 5 w 1448 8
    VA 110 2.25″ x 1.5″ x 1.8″ 95 GPH 36 in. 5.5 w 1458 7
    VA 120 2.25″ x 1.5″ x 1.8″ 100 GPH 36 in. 9 w 1459 4
    VA 150 3.25″ x 2 ” x 2.75″ 180 GPH 71 in. 10.2 w 1465 5
    VA 180 2.25″ x 1.25″ x 1.7″ 80 GPH 24 in. 5 w 2113 4
    VA 230 2.5″ x 1.4″ x 1.8″ 94 GPH 30 in. 5.5 w 2929 1
    VA 360 3″ x 1.8″ x 2.35″ 152 GPH 42 in. 8 w 1874 5
    VA 480 3″ x 1.8″ x 2.35″ 200 GPH 50 in. 11 w 1875 2
    VA 610 3″ x 1.8″ x 2.5″ 223 GPH 50 in. 12 w 2604 7
    VA 820 3″ x 1.8″ x 2.5″ 237 GPH 56 in. 13 w 2605 4
    VA 1300PP 4.25″ x 2.25″ x 2.75″ 370 GPH 72 in. 24 w 1888 2
    VA 1800 6″ x 2.5″ x 3.5 “ 480 GPH 72 in. 28 w 2115 8
    VA 2300 6″ x 2.5″ x 3.5 “ 600 GPH 72 in. 41 w 2114 1
    VA 2600 7″ x 3 ” x 3.6 “ 740 GPH 94 in. 46 w 1877 6
    VA 3300 7″ x 3 ” x 3.6 “ 977 GPH 136 in. 75 w 1878 3
    VA 3600 7″ x 3 ” x 4.125 “ 1057 GPH 156 in. 80 w 1879 0
    VA 4900 7″ x 3 ” x 4.125 “ 1321 GPH 168 in. 113 w 1880 6
    VA 8000 12″ x 6 ” x 6.75″ 2200 GPH 15 ft. 176 w 1396 2
    • UL Model:

      model Item no. Dimension
      (L x W x H)
      Flow rate max.
      head
      wattage UPC# 0069037
      VA 60UL 1.75″ x 1.5″ x 1.25″ 60 GPH 23 in. 4.2 w 1471 6
      VA 90UL 2″ x 1.5″ x 1.75″ 90 GPH 24 in. 9.6 w 1473 0
      VA 100UL 2.25″ x 1.5″ x 1.8″ 100 GPH 40 in. 5 w 1469 3
      VA 120UL 2.25″ x 1.5″ x 1.8″ 100 GPH 36 in. 9 w 1475 4
      VA 150UL 3.25″ x 2 ” x 2.75″ 180 GPH 71 in. 10.2 w 1476 1
    • Instruction:https://www.commodityaxis.com/images/PDF/PowerHead_pump_booklet.pdf

    • If you have problem opening PDF file from Internet Explorer,
      please try Firefox or right click on the link and select Save Target As and save the PDF file in your computer.
    ]]>